Your Trusted Partner in Medical Equipment Supply!

Philips Big Bore RT

Philips Big Bore RT

0.00

Philips Big Bore RT is a high-performance CT simulation system designed specifically for radiation oncology. With its large 85 cm bore, enhanced imaging accuracy, and AI-driven workflow automation, it enables precise treatment planning, patient comfort, and seamless integration with radiotherapy systems.

Share Product :

Facebook
WhatsApp
X
Telegram
LinkedIn

Description

Big Bore RT is designed as a CT simulator to enhance clinical confidence, accelerate time to treat and maximize value of its investment without compromising on patient experience – four dimensions that are essential towards excellent care.

Features

Focusing on what matters in radiation oncology

Big Bore RT offers advanced tools to facilitate accurate efficient patient marking and simulation workflow. Featuring 60 cm true scan FOV for full anatomic visualization. It provides spatial positioning accuracy of less than 2mm between the imaging plane and the laser marking plane for confidence in patient marking. This meets the AAPM TG 66.

Where imaging and treatment planning meet

While excellent image quality is the foundation for accurate contouring and treatment plans, radiation oncology demands more. The Big Bore RT offers superb imaging and simulation solutions that integrate with your department workflow for the accuracy and efficiency cancer care requires.

Accelerate time to treatment

Efficiently move from scan to plan with virtual simulation and patient marking integrated at the scanner. Multimodality Simulation Workspace is a vendor-neutral image simulation platform that supports image fusion and contouring for all available images and data sets. It provides clinical teams with the tools necessary for multimodality image fusion, AI-driven, auto-contouring, and efficient collaborations helping to reduce patient wait time while providing quality care.

Enhance accuracy in treatment planning and therapy delivery

Through low-contrast resolution, lower dose/higher image quality, and virtually noise-free* images, iterative model reconstruction (IMR) technology delivers visualization of fine detail and improved clinical accuracy in the detection and delineation of small, subtle structures. IMR improves image quality and advances ‘autosegmentation’. Less manual intervention means fast contouring and short time to treatment.

Managing motion for treatment confidence

4D CT with bellows and amplitude binning, include in the pulmonary tool kit for Oncology, helps improve accuracy in treatment planning and therapy delivery, even in irregular breathers.

Advance user comfort and proficiency during interventional procedures

The interventional controls designed for the Big Bore RT offers user flexibility, workflow efficiency and automatic position transcribing. With accurate and fine incremental movements of the table available at the click of a button, to quickly and clearly visualize the needle tip during interventional procedures, clinicians can focus on what matters most, the patient.

The Power of Two

Philips provides two leading technologies that can improve image quality. iDose4 improves image quality through artifact prevention and increased spatial resolution at low dose. O-MAR reduces artifacts caused by large orthopedic implants. Together they product high image quality with reduced artifacts.

Focus on the patient…workflow powered by iPatient

iPatient provides patient-centered imaging – including imaging for simulation and treatment planning – providing consistent image quality from scan to scan. iPatient features a simple user interface to manage image quality, dose, and speed of acquisition. Drive confidence and consistency with dedicated exam cards for oncology as well as diagnostic CT procedures.

Reviews

There are no reviews yet.

Be the first to review “Philips Big Bore RT”

Your email address will not be published. Required fields are marked *